Veterinary Medical Solution Supplier

NEO ECG WMV660H Vet ECGTablet

Share:

PRODUCT DETAILS

Funtion Features

* 10.1” high resolution color touch screen, easy to operate.Portable design, compact in size.

* Can be powered by an external DC power supply, a built-in rechargeable lithium battery.

* Support synchronous acquisition and display of 7 lead waveform, as well as heart rate detection.

* Support automatic pacing detection and marking.

* Support auto, RR analysis, HRV, medicine test, ECG event mode.

* Provide 4 sampling modes: pre-sampling, real-time sampling, periodic sampling and trigger sampling.

* Input patient information via virtual alphanumeric keyboard and barcode scanning.

* Freeze the ECG waveform on the screen.

* Output files in multiple formats, such as Carewell ECG, PDF, BMP, HL7, DICOM, SCP.

* Store, preview, review, edit, export, upload, print and search patient data.

* Support wireless transmission of ECG data via WiFi and mobile networks.

* Support laser printer via USB port.

* Export patient data to USB flash disk via USB connector.

Technical Specification

Main unit

Main unit

±1

Leads

7 lead synchronous acquisition

A/ D conversion

24 bits

Sampling rate

32000 samples/Sec

Common mode rejection ratio

≥140dB (AC filter on),≥120dB(AC filter off)

Time constant

≥5s

Frequency response

0.01HZ~350HZ(+0.4db-3.0db)

Sensitivity

Auto,2.5mm/mV,5 mm/mV,10 mm/mV,20

mm/mV,40 mm/mV, less than ±5% error

Filter

AC filter:50Hz,60Hz,Off

EMG filter: 25Hz,35Hz,45Hz,Off

ADS flter: 0.01 Hz,0.05 Hz,0.32 Hz,0.67 Hz

Low pass fillter:75Hz,100Hz,150Hz,300Hz,Off

Paper speed

5mm/s.6.25mm/s.10mm/s.12.5mm/s.

25mm/s and 50mm/s, less than ±3% error

Input Impedance

≥100MΩ(10Hz)

Input Circuit Current

≤10nA

Calibration voltage

1mV±2%

Depolarization voltage

±900mV,±5%

Noise

≤12.5μV

Amplitude quantisation

0.95 μV/LSB



Recovery time after defibrillation discharge

<10s

Pacer pulse display

Pacing pulse with amplitude of

±2mV~±700mV, duration of 0.1ms-2.0ms,A-5

rise time of less than 100μs, and frequency of

100/min can be displayed on the ECG recording.

Minimum detectable signal

20μVp-p

Size & Weight

10.1" Tablet

Size:272.6mm(L)*181.2mm(W)*25.8mm(H)

Net Weight:1.2Kg

10.1" Base

Size:274mm(L)* 288mm(W)*111.2mm(H)

Net Weight:2.5Kg


Intelligent diagnostic results

NEO ECG WMV660H Vet ECGTablet
Atrioventricular hypertrophy

1. Left atrial hypertrophy

2. Right atrial hypertrophy

3. Biatrial hypertrophy

4. Left ventricular hypertrophy

5. Right ventricular hypertrophy

6. Biventricular hypertrophy

NEO ECG WMV660H Vet ECGTabletMyocardial infarction

1. Abnormal Q wave

2. Anterior wall myocardial infarction (acute, recent, obsolete)

3. Anterior wall infarction (acute, recent, obsolete)

4. Antero-septal myocardial infarction (acute, recent, obsolete)

5. Lateral myocardial infarction (acute, recent, obsolete)

6. Inferior wall myocardial infarction(acute, recent, obsolete)

NEO ECG WMV660H Vet ECGTabletArhythmia

Abnormal heart rate of origin

1. Nodal tachycardia

2. Sinus bradycardia

3. Sinus arrhythmia

4. Ventricular Arrest

5. Atrial flutter

6. Atrial fibrillation

7. Veatricular flutter

8. Ventricular fibrillation

9. (Atrial, Junctional, Ventricular) escape rhythm

10. (supraventricular,Ventricular)extrasystolic bigeminy

11. (supraventricular,Ventricular)extrasystolic trigeminy

12. (supraventricular,Ventricular)couplets premature beat

13. Atrial tachycardia

14. (supraventricular,Ventricular)tachycardia

15. Non-paroxysmal junctional tachycardia

16. Accelerated idioventricular rhythm 

NEO ECG WMV660H Vet ECGTabletMyocardial ischemia

ST segment and T wave changes

Light & portable

Thickness ≤27mm, weight ≤1kg, endurance ≥10H

Simple operation

One-click thermal printing

Waveform restoration

High precision sampling ≥ 32K, high

bandwidth ≥ 350Hz,24-bit A/D conversion

Intelligent management

Support more than 10000 ECG records

management, support fuzzy search


   